LC XP Level Switch for high pressure systems

LC XP Oil level switchThe LC XP series of optical level switches are specially designed for use in level monitoring for controlling the oil level of CO2 compressors or the refrigerant charge of the system.
They can be mounted directly on the crank case of the compressors or on the oil separator/liquid receiver.

They have bodies made of steel and a glass dome.

The two parts design allow the fast replacement of the electronic parts without  depressurizing the system.
The model combines high temperature range (up to 125°C) with variety of possible threads (simply by changing the front part).

Main Features
  • The absence of mechanical moving parts ensures High reliability
  • Well consolidated steel with fused glass technology ensures no leakage and good chemical compatibility.
  • Electronic sensor can be easily replaced without empty and/or depressurize the plant due to the two parts design.
  • Extended working temperature range
  • No need for calibrations on the field
  • Direct mounting onto various types of compressors with 1”1/8 – 18 UNEF adapter and tanks with 1/2”NPT adapter
  • Customizable delays on request
  • Unit conform to directives: * 2004-108-CE * CEI EN 60204-1:2006
Click here to download a PDF technical sheet of the LC XP oil level switch (520 Kb)

LC XP oil level switch - Technical Data of the Instrument

Supply voltage : 230VAC@50Hz / 115VAC@60Hz / 24 VAC@50/60Hz / 24VDC depending on selected model
Electronic Protections : Over voltage protection
Electrical connection : EN 175301-803A connector (EX DIN 43650 size A)
Output signal : Solid state output Normally Open or Normally Close in air
Supply Current : 20mA max. during normal operation
Output max. current : Up to 100 mA
Housing material : Nickel plated steel
Enclosure protection class : IP 65
Working temperature range : -40°C÷ +125°C
Max pressure : 120 bar (for higher pressures, please contact the supplier)
Torque tighten : 50 Nm for adapter installation on the system. Hand Screw with strength the sensor to the adapter
LC XP mechanical dimensions
LC XP mechanical dimensions

 
Copyright 2008-2011 - Teklab S.r.l. - Via Emilia Ovest, 1179 - 41123 Modena - Italy - P.IVA 01976750362 - Company Register of Modena n. 01976750362 - Paid-in Capital Euro 10.000 i.v.